View previous topic :: View next topic
|
| Author |
Message |
vishwas.jeevannavar
Joined: 20 May 2008 Posts: 3
|
Posted: Tue May 20, 2008 9:02 pm Post subject: structural details |
    |
|
hi people,
myself vishwas here doin my 6th sem in architecture. This semester we have got our dsgn project as a multipurpose indoor stadium. So i am findin a bit of problem with the structural part of the roof. So can you pls help me out. |
|
| Back to top |
|
 |
J.Saravana Balaji
Joined: 25 Dec 2007 Posts: 21 Location: India
|
Posted: Fri May 23, 2008 4:22 am Post subject: |
    |
|
We have recently designed and constructed a multipurpose indoor stadium in A.P India.The span is about 62 mts x 100 mts.This along with other structures in the campus were designed and constructed with in 126 days.
The roofing system we adopted hereis sandwiched MS panels over a space structure.The outer to outer dimension of the space frame (depth) is approx 3 mts.This could be Ideal for a stadium as they are easy for errection and maintenance.
Even masted structures with membrane roofing are also suitable for an indoor stadium |
|
| Back to top |
|
 |
vishwas.jeevannavar
Joined: 20 May 2008 Posts: 3
|
Posted: Sat May 24, 2008 11:49 pm Post subject: |
    |
|
| Hello Mr.Balaji thank you for sparing your time and replying for the mail.. hope the information will help me out.. thank you once again.. |
|
| Back to top |
|
 |
|